dimensions in inches and (millimeters) version: a06 GBU1001 - gbu1007 single phase 10.0 amps. glass passivated bridge rectifiers gbu .880(22.3) .860(21.8) 9 typ. .080(2.03) .065(1.65) .710(18.0) .690(17.5) .085(2.16) .075(1.90) .022(0.56) .018(0.46) .160(4.1) .140(3.5) .050(1.27) .040(1.02) 0.125(3.2)x45 chamfer .190(4.83) .210(5.33) .100(2.54) .085(2.16) .075 (1.9)r .020r(typ.) .310(7.90) .290(7.40) .085(2.16) .065(1.65) .740(18.8) .720(18.3) .080(2.03) .060(1.52) .140(3.56) .130(3.30) features ul recognized file # e-96005 ideal for printed circuit board reliable low cost construction plastic material has underwriters laboratory flammability classification 94v-0 high case dielectric strength of 1500vrms surge overload rating to 200 amperes peak high temperature soldering guaranteed: 260 o c / 10 seconds / .375?, (9.5mm) lead lengths. mechanical data case: molded plastic body. terminals: plated leads solderable per mil-std-750, method 2026. weight: 0. 3 ounce, 8.0 grams mounting torque: 5 in. lb. max. maximum ratings and electrical characteristics rating at 25 o c ambient temperature unless otherwise specified. single phase, half wave, 60 hz, resistive or inductive load. for capacitive load, derate current by 20% type number symbol gbu 1001 gbu 1002 gbu 1003 gbu 1004 gbu 1005 gbu 1006 gbu 1007 units maximum recurrent peak reverse voltage v rrm 50 100 200 400 600 800 1000 v maximum rms voltage v rms 35 70 140 280 420 560 700 v maximum dc blocking voltage v dc 50 100 200 400 600 800 1000 v maximum average forward rectified current @t c = 100 o c i (av) 10.0 a peak forward surge current, 8.3 ms single half sine-wave superimposed on rated load (jedec method ) i fsm 220 a maximum instantaneous forward voltage @ 5.0a @ 10a v f 1.0 1.1 v maximum dc reverse current @ t a =25 o c at rated dc blocking voltage @ t a =125 o c i r 5.0 500 ua ua typical junction capacitance (note 3) cj 211 94 pf typical thermal resistance per leg ( note 1 ) ( note 2 ) r ja r jc 21 2.0 o c/w operating temperature range t j -55 to +150 o c storage temperature range t stg -55 to + 150 o c notes 1: units mounted in free air no heat sink on pcb 0.5?x 0.5 ? (12mm x 12mm) copper pads, 0.375?(9.5mm) lead length. 2: device mounted on 4? x 6? x 0.25? plate heatsink. 3. measured at 1.0 mhz and applied reverse voltage of 4.0v.
ratings and characteristic curves (GBU1001 thru ) gbu1007 fig.3- maximum non-repetitive forward surge current per bridge element 1 5 100 case temperature. ( c) o fig.1-maximum forward current derating curve number of cycles at 60hz fig.2- typical reverse characteristics per bridge element instantaneous reverse current .( a) peak for ward surge current . (a) average for ward current . (a) 50 20 10 2 0 2 6 10 0 100 50 150 0.01 0.1 10 100 500 1 02040 60 80 100 percent of rated peak reverse voltage. (%) tj=150 c 8.3ms single half sine wave fig.5- typical instantaneous forward characteristics per bridge element instantaneous for ward current . (a) 4 20 40 100 10 2 1 0.4 0.2 0.1 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 instantaneousforward voltage. (v) tj=25 c 0 pulse width=300 s 1% duty cycle tj=25 c 0 tj=150 c 0 50-400v 600-1000v heat-sink mountg 100mm x 100mm x 1.6 mm cu. plate 8 4 225 200 175 150 125 100 75 50 120 version: a06 fig.4- typical junction capacitance 1 2 5 10 20 800 100 1000 600 500 400 300 200 100 0 reverse voltage. (v) 200 500 junction cap acitance.(pf) tj=25 c 0 50 0.1 0.5 g bu 1005- g bu 1007 g bu 1001- g bu 1004
|